Doorway / InSite Code |
Label |
Description |
Units |
Default Value |
Range |
C1 |
SPOC |
Occupied setpoint |
- |
50 |
Re-scalable |
C2 |
MXPV
|
Maximum Sensor Scaling (value @10V)
|
- |
100 |
Re-scalable |
C3 |
MNPV
|
Minimum Sensor Scaling (value@0V)
|
- |
0 |
Re-scalable |
C4 |
DPPV
|
Decimal places for engineering scaling |
- |
1 |
0 to 4 |
C5 |
MXSP
|
Maximum setpoint value |
- |
100 |
Re-scalable |
C6 |
MNSP
|
Minimum setpoint value |
- |
0 |
Re-scalable |
C7 |
MNOP
|
Minimum Output |
% |
5 |
0 to 100 |
C8 |
INVL
|
Invert control sense:
0: increasing error reduces output
1: increasing error increases output |
- |
0 |
0 to 1 |
C9 |
ELAG |
Percentage lag or lead for second output |
% |
0 |
-50 to 50 |
C10 |
HPRD
|
Stroke time or minimum on time for driver
|
Secs/10 |
- |
1 to 60 |
C11 |
HDLY
|
Interlock delay:
Negative value delays fan (or pump) after heating starts
Positive value cause run on of fan after heating shuts down |
Mins |
0 |
-30 to 30 |
C12 |
CPRD
|
Stroke time or minimum on time for driver |
Secs/10 |
- |
1 to 60 |
C13 |
CDLY
|
Interlock delay:
Negative value delays fan (or pump) after cooling starts
Positive value cause run on of fan after cooling shuts down |
Mins |
0 |
-30 to 30 |
C14 |
MANL
|
Manual level , from Doorway
|
% |
0 |
0 to 100 |
C15 |
TYPE |
Pump(set) switching type:
(when regd to BLR/DIN/STD or HIL):
1: Primary Pump(s)
2: VT Pump(s)
(when regd to special BLR/DIN/DHW)
3: DHW Pump(s)
(when regd to VTC, VTU or CTU)
4: Heating Optimum Start
5: Heating Occupation only
6: Heating Demand >5%
(when regd to CLR, VTU or CTU)
7: Cooling Optimum Start
8: Cooling Occupation only
9: Cooling Demand >5% |
- |
1 |
1 to 9 |
C16 |
ACNL |
Analogue Channel select:
1: select channel b terminals 5+6
2: select channel a terminals 3+4
|
- |
0 |
0 to 2 |
C17 |
ALRM
|
Alarm mode:
0: ignore alarms
1: report alarms
2: report alarms, shut down all outputs on alarm
3: report alarms, shut down all outputs on STOP alarm or sensor fail alarm |
- |
0 |
0 to 3 |
C18 |
ALST
|
Not used in this application |
- |
1 |
0 to 1 |
C19 |
MXVA |
Maximum Voltage output a |
Vdc |
10 |
0 to 10 |
C20 |
MNVA |
Minimum Voltage output a |
Vdc |
0 |
0 to 10 |
C20 |
MXVB |
Maximum Voltage output b |
Vdc |
10 |
0 to 10 |
C21 |
MNVB |
Minimum Voltage output b |
Vdc |
0 |
0 to 10 |
Doorway / InSite Code |
Label |
Description |
Units |
Default Value |
Range |
I2 (C31)
|
OCCD
|
Occupied
|
- |
- |
0 to 1 |
I3 (C32)
|
WMUP |
Optimum Start |
- |
- |
0 to 1 |
I6 (C35)
|
RLYA |
Triac A Status (special order 3T versions only) |
- |
- |
0 to 1 |
I7 (C36)
|
RLYB |
Triac B Status (special order 3T versions only) |
- |
- |
0 to 1 |
I8 (C37)
|
RLYC
|
Triac C Status (special order 3T versions only) |
- |
- |
0 to 1 |
W1 (C38)
|
AUTO
|
Automatic/Manual Status
|
- |
- |
0 to 1 |
W2 (C39)
|
OVRD
|
Override
|
- |
- |
0 to 1 |
W5 (C42) |
HAND |
Manual Hand; use with MANL to set output level |
-
|
0 |
0 to 1 |
W6 (C43) |
POT |
not used in this application |
-
|
1 |
0 to 1 |
W7 (C44) |
SERV |
Service Pin Message (to Doorway and InSite, self
resetting) |
-
|
-
|
0 to 1 |
S1* (C50) |
PVKP |
Pressure reading |
-
|
- |
Re-scalable |
S2* (C51)
|
HCOP |
Control output to drivers |
%
|
- |
-100 to 100 |
S3 (C52)
|
RQKP |
Controller current setpoint |
- |
- |
Re-scalable |
S4 (C53)
|
DMND |
Speed |
%
|
- |
0 to 100 |
K1 (C60)
|
SPOC |
Occupied setpoint |
- |
50 |
Re-scalable |
K2 (C61) |
MXPV
|
Maximum Sensor Scaling (value @10V)
|
- |
100 |
Re-scalable |
K3 (C62) |
MNPV
|
Minimum Sensor Scaling (value@0V)
|
- |
0 |
Re-scalable |
K4 (C63) |
DPPV
|
Decimal places for engineering scaling |
- |
1 |
0 to 4 |
|
|
Engineering Parameters; only accessible via Doorway
and InSite |
|
|
|
C90
|
NOAL
|
No Alarms; all alarms cleared when set to 1
|
- |
- |
0 or 1 |
C91
|
SENF
|
Sensor Failed (when set to 1)
|
- |
- |
0 or 1 |
C92
|
EXTN |
Volt-Free Contact alarm (when set to 1) |
- |
- |
0 or 1 |
C93
|
STOP |
STOP alarm received (when set to 1)
|
- |
- |
0 or 1 |
|
|
* 24 hour plots available for these values by default |
|
|
|
|
|
Plotting interval and plotted variable changeable
via Doorway or InSite |
|
|
|