Network Alarm Annunciator

with 3 x Triac Outputs

Configuration Tables

Doorway / InSite Code

Label

Description

Units

Default Value

Range

C1
ALMF
Alarm Filter; used to set filter to accept alarms from specific types of Modules:
0: Accept All Alarms
1: Alarms from Networked T+Rh sensors only
2: Alarms from Monitoring Modules only
3: Alarms from Cool Sources (and their Submodules) only
4: Alarms from Heat Sources (and their Submodules) only
-excluding Boiler Controller with Housekeeping
5: Alarms from Boiler Controller with Housekeeping (and its Submodules) only
6: Alarms from Networked Outside Sensors only
7: Alarms from Serial Adaptors only
8: Alarms from AHU Controllers (and their Submodules) only
9: Alarms from Zone, Slave Zone, DHW and FCU Controllers (and their Submodules) only
-
-
0 to 9
C2
ALRM
Alarm Mode for local alarm input ONLY.
0=ignore alarms
1= report alarms
-
0
0 to 1
C3
ALST
Alarm status of Local Alarm Input i.e. 1=Shorted
-
1
0 to 1
C4
ALDF
Alarm defeats filter. Set 1 allows local input alarms to bypass alarm filter and be placed in the alarm list.
-
0
0 to 1

Monitoring Parameters

Doorway / InSite Code

Label

Description

Units

Default Value

Range

I1 (C30)
IN A
Local Alarm Input status
-
-
0 to 1
I6 (C35)
ALMS
Alarm Received Relay status (1=on)
-
-
0 to 1
I7 (C36)
ALCR
Alarm Current Relay status (1=on)
-
-
0 to 1
W7 (C44)
SERV
Generate Service Pin message
-
0
0 to 1
W8 (C45)
CGST
Configuration Mode status
-
0
0 to 1
C50
Alarm 1 source
Shows the source Module that sent stored alarm no.1
Alarm Module stores 15 alarms; no. 1 is the oldest and will be overwritten when a new alarm appears. 4 character label will be updated automatically to show source, value displayed indicates address of the source:
Label {value } Source Device
TRH {n }: = Networked T+Rh Sensor, address n
MON {n }: = Monitoring Module, address n
HSC {n }: = Heat Source, address n
CSC {n }: = Cool Source, address n
SEN {n }: = Networked Outside Sensor, address n
ZON{n }: = Zone, Slave Zone, DHW or FCU Controller, address n
AHU {n }: = AHU Controller, address n
BLR {n }: = Boiler Controller (with Housekeeping), address n
SLT {n }: = Serial Adaptor, address n
DEV {0 }: = Unknown Device, address unknown
-
-
0 to 9999
C51
Alarm 1 type
Shows the type of alarm (its name and condition) stored as alarm no.1:
Alarm Module stores 15 alarms; no. 1 is the oldest and will be overwritten when a new alarm appears. 4 character label will be updated automatically and alternates between showing alarm name and alarm condition, value displayed indicates value of temperature etc. as the alarm occurred, if appropriate, or zero if not applicable :
Label : Alarm Condition
ALRM = Digital Alarms and any alarm where condition is not needed (e.g Filter Fail alarm from AHU)
HIGH = High Alarms from a sensor
LOW = Low Alarms from a sensor
BUST = Sensor Failed Alarm
EOFW = Special Diagnostic Alarm, SeaChange use only
-
-
0 to 9999
C52
Alarm 2 source
Source of stored alarm no. 2 (see C50)
-
-
0 to 9999
C53
Alarm 2 type
Type of stored alarm no. 2 (see C51)
-
-
0 to 9999
C54
Alarm 3 source
Source of stored alarm no. 3 (see C50)
-
-
0 to 9999
C55
Alarm 3 type
Type of stored alarm no. 3 (see C51)
-
-
0 to 9999
C56
Alarm 4 source
Source of stored alarm no. 4 (see C50)
-
-
0 to 9999
C57
Alarm 4 type
Type of stored alarm no. 4 (see C51)
-
-
0 to 9999
C58
Alarm 5 source
Source of stored alarm no. 5 (see C50)
-
-
0 to 9999
C59
Alarm 5 type
Type of stored alarm no. 5 (see C51)
-
-
0 to 9999
C60
Alarm 6 source
Source of stored alarm no. 6 (see C50)
-
-
0 to 9999
C61
Alarm 6 type
Type of stored alarm no. 6 (see C51)
-
-
0 to 9999
C62
Alarm 7 source
Source of stored alarm no. 7 (see C50)
-
-
0 to 9999
C63
Alarm 7 type
Type of stored alarm no. 7 (see C51)
-
-
0 to 9999
C64
Alarm 8 source
Source of stored alarm no. 8 (see C50)
-
-
0 to 9999
C65
Alarm 8 type
Type of stored alarm no. 8 (see C51)
-
-
0 to 9999
C66
Alarm 9 source
Source of stored alarm no. 9 (see C50)
-
-
0 to 9999
C67
Alarm 9 type
Type of stored alarm no. 9 (see C51)
-
-
0 to 9999
C68
Alarm 10 source
Source of stored alarm no. 10 (see C50)
-
-
0 to 9999
C69
Alarm 10 type
Type of stored alarm no. 10 (see C51)
-
-
0 to 9999
C70
Alarm 11 source
Source of stored alarm no. 11 (see C50)
-
-
0 to 9999
C71
Alarm 11 type
Type of stored alarm no. 11 (see C51)
-
-
0 to 9999
C72
Alarm 12 source
Source of stored alarm no. 12 (see C50)
-
-
0 to 9999
C73
Alarm 12 type
Type of stored alarm no. 12 (see C51)
-
-
0 to 9999
C74
Alarm 13 source
Source of stored alarm no. 13 (see C50)
-
-
0 to 9999
C75
Alarm 13 type
Type of stored alarm no. 13 (see C51)
-
-
0 to 9999
C76
Alarm 14 source
Source of stored alarm no. 14 (see C50)
-
-
0 to 9999
C77
Alarm 14 type
Type of stored alarm no. 14 (see C51)
-
-
0 to 9999
C78
Alarm 15 source
Source of stored alarm no. 15 (see C50)
-
-
0 to 9999
C79
Alarm 15 type
Type of stored alarm no. 15 (see C51)
-
-
0 to 9999
 
 
Engineering Parameters; only accessible via Doorway and InSite
 
 
 
C90
NOAL
No Alarms from the Local Input when set to 1
(but module may still have current alarms from other modules on the network as indicated by the Alarm Received/Alarm Current outputs)
-
-
0 to 1
C91
GENA
Local Input in alarm (when set to 1)
-
-
0 to 1